Mail and web server monitoring

Top  Download  Previous  Next

#### Counters for monitoring mail and web servers

Axence nVision® has several special counters for monitoring mail and web servers. These counters do not only connect to the server, but also perform tests to check whether the server works correctly: they measure the page load time and check the page content, check the list of incoming e-mails and send a test e-mail. To run such tests, create the corresponding counter on the Performance counters tab in the Device information window. For more information about these counters and tests, see Counter types. For information about creating counters, see Performance counter management.

#### Counter types

The list below describes only the Service test group, used to monitor mail and web servers. For information about the other groups (Device availability and Counters), see Performance counters and device status.

Service test

Page load time

Measures the time needed to load a specified page.

Page content change

Checks whether the page content has changed.

POP3 logon time

Measures the time needed to log on to a mail server.

E-mail send time

Measures the time needed to send a test e-mail.

Test HTTPS connection

Tests an HTTPS connection, with the option to specify a client certificate.

Device-specific counters

Some counters contain all the information needed to check them, including the device address. These are device-specific counters. In general, all Service test counters are device-specific (for example, the Page load time counter).

#### Counter properties

The properties of the individual counter types in the Service test group:

hmtoggle_plus1Page load time

hmtoggle_plus1Page content change

hmtoggle_plus1POP3 logon time

hmtoggle_plus1E-mail send time

Test HTTPS connection

The counter tests an HTTPS connection, with the option to specify a client certificate.

Property

Description

Page address

The page address beginning with https://.

Use client certificate

Turn on this option to use a client certificate.

Certificate file

Select the certificate file.

Key file

Select the key file.

Root certificate file

Select the root certificate file.

Test connection

Click on this button to test the connection.

Monitoring interval

If you select Auto, Axence nVision® manages the monitoring time so that checks are frequent enough (depending on the number of monitored devices). To set a specific value, select Set and enter the value in the edit field.