Device status concept

Top  Download  Previous  Next

Device status as a calculated value

In Axence nVision®, device status can be changed by events. You can define the conditions in which a device gets the <Unknown>, <Up>, <Down> or <Warning> status. The device status also changes depending on the status of the monitored services.

Automatic status change

The device status is initially set to <Unknown>. It changes when Axence nVision® starts monitoring services. As soon as the first service is checked and is up, the status changes to <Up>. The <Warning> status means that some services are down, but at least one service is up. The status changes to <Down> if no service is up.

Status change by events

Axence nVision® determines the device status also on the basis of currently generated alerts. To use this, set the Change device status to field in each event. When an alert for the event is generated, the device status can change to the defined value.

You can set three values in this field: <No change>, <Warning> and <Down>. The <Down> status has the highest priority: if at least one event has this status, the device status also changes to <Down> (regardless of the status of the monitored services). If several events with the <Warning> and <Down> statuses are generated, the device status is <Down>. If only events with the <Warning> status were generated, the device status changes to <Warning> (unless it is already <Down> because of services that are down – then it stays <Down>).